| Industrial Lubrcants |
JETSTREAM 17000
Extended Service Life Premium Quality Turbine Oil
QUANTUM Jetstream 17000 is extended service life turbine oil specially developed to completely satisfy the severe lubrication requirements of steam, hydroelectric and frame type gas turbines couple with gearing system.
They are manufactured with highly-refined unconventional base oils and specially selected high performance additives to provide good viscosity/temperature characteristics, rapid air release, good water separation, excellent oxidation stability and excellent rust and corrosion resistance.
Applications
Recommended for use in all steam, hydroelectric frame type and gas turbines and solar turbines requiring non-antiwear types turbine oils. Also suitable for use in speed reducers, air compressors, vacuum and deep well pump, electric motors, lightly loaded plain bearings and other equipment requiring turbine oil quality.
Customer Benefits
- Superior oxidation control and thermal stability - longer life, deposits free
- Extended oil service life and reduced operating and maintenance cost
- Superior water separation capability - less processing and disposal cost ( minimize purification needs)
- Low foaming and rapid air release - full fluid lubrication (enhance performance) in high-speed bearings and meshing gear teeth.
Product Typical
|
Characteristics |
ISO Viscosity Grade |
| 68 |
| Density @ 15 C, kg/l |
0.874 |
| Pour Point, C |
-9 |
| Flash Point, C |
226 |
| Kinematic Viscosity, cSt |
|
| @ 40 C |
73.0 |
| @ 100 C |
9.0 |
| Viscosity Index |
106 |
| TAN, mgKOH/g |
0.07 |
| Rust Test |
Pass |
| Foaming characteristics, ml |
|
| Sequence I |
0/0 |
| Sequence II |
30/0 |
| Sequence III |
0/0 |
| Water Separability |
40/40/0 (20) |
| RBOT, minutes |
1226 |
| +Oxidation Control (TOST), hrs |
> 15,000 |
The product typical may change without notice; however the performance of the product would meet & exceed the OEM requirements.
Will meet the requirements of:
- General Electric GEK 32568 F
- DIN 51515
- BS 489 (CIGRE)
- Solar Turbines ES 9-224
- Brown Boveri HTGD 90117
|
|
|
 |
|
|